HART® output, 0-100 thru 100K psi, Hazardous Location Approvals
Designed for applications including offshore oil rigs, oil production platforms, natural gas pipelines and rig safety systems, 970 uses a solid machined stainless steel diaphragm.
Features
High Accuracy
Many Options available
All Stainless Steel construction
IP-68 Rated
High Pressure Applications
Full Scale Pressure Range: 0-100 thru 0-100K, PSIA, PSIS (0-6.89 thru 0-6894 bar)
Turndown (≤20K PSI): 4:1 with no degradation in static accuracy or thermal effect
Static Accuracy:
- ≤±0.1% FSO (combined linearity, hysteresis and zero repeat)
- ≤±0.25% FSO (Ranges 25,000 PSI & Up)
Full Scale Output (FSO):
- 16 mA ±0.1% FSO
- 16 mA ±0.5% FSO
Dynamic Response Time: ≤300 mSec to reach 63% FSO
Temperature Effect on Zero: ≤±1% FSO per 100°F (37°C)
Temperature Effect on Span: ≤±1% FSO per 100°F (37°C)
Compensated Temperature: 70°F to 170°F (21°C to 76°C)
Operating Temperature: -40°F to 190°F (-40°C to 87°C)
Storage Temperature Limit: -65°F to 250°F (-53°C to 121°C)
Supply Voltage: 11.5 to 28 Vdc
Power Supply Regulation Effect: ≤±0.02% FSO per Volt
Output Signal: 4 – 20 mA
Bridge Impedance: 5000 Ohms nominal
Circuit Protection: Varistor protected across the input leads for surges above 40 V and currents to 250 Amps peak with a pulse width of 20 μSecs. Reverse polarity protected.
Insulation Resistance: >200 MegOhms to case ground
Electrical Connection: 1/2″ NPT (M), 18 AWG wire, 72″
Wire Color Codes:
Red +Power/Signal
Black -Power/Signal
Green Case ground
White No Connection
Pressure Connection:
- 0-50 thru 0-15K PSI (1/4″ – 18 NPT Female (0-3.3 thru 0-1034 bar))
- 0-20K thru 0-50K PSI (1/4″ F250-C High Pressure Tube (0-1378 thru 0-3447 bar))
- 0-60K thru 0-100K PSI (5/16″ F312C High Pressure Tube (0-4136) thru 0-6894 bar))
Proof Pressure:
- 0-100 thru 0-15K PSI (1.5 times FSPR or 20K PSI (1378 bar), (0-6.8 thru 0-1034 bar) whichever is less)
- 0-20K thru 0-100K PSI (1.2 times FSP (0-1378 thru 0-6894 bar))
Burst Pressure:
- 0-100 thru 0-15K PSI (≥ 2.3 to 5 times FSPR dependent on (0-6.8 thru 0-10342 bar) sensor)
- 0-20K thru 0-100K PSI (1.5 times FSPR or 125K PSI (8618 bar) (0-1378 thru 0-6894 bar) whichever is less)
Mounting: Supported by process piping or optional mounting bracket
Enclosure:
- 0-100 thru 0-15K PSI (15-5 PH and 316 stainless steel (0-6.8 thru 0-1034 bar))
- 0-20K thru 0-100K PSI (316 SST and PH 13-8 Mo SST (0-1378 thru 0-6894 bar))
Wetted Parts:
- 0-100 thru 0-15K PSI (15-5 PH stainless steel (0-6.8 thru 0-1034 bar))
- 0-20K thru 0-100K PSI (PH 13-8 Mo SST (0-1378 thru 0-6904 bar))
Shock Limitation: 100 G’s
Weight: 24 oz. (0.680 kilograms)
Identification: Laser etched onto body
Enclosure: Classification NEMA 4X
DF: Bleed port (10K PSI and below)
DG: Improved temperature compensation (<5%/100°F for zero/span)
DH: Special range
DQ: Cleaning for oxygen service
EA: Special calibration run
JJ: Direct mount indicator with explosion proof housing
JS: Direct mount indicator
ME: CSA explosion proof label
MR: Modified electrical damping
NG: ATEX flameproof label
NH: Customer specified identification
NJ: CE label
NK: ATEX intrinsic safety label
NX: CSA intrinsic safety label
NY: FM explosion proof label
NZ: FM nonincendive label
PW: 1/8 DIN digital indicator (consult factory)
QA: 316 stainless steel wetted parts
QB: Inconel (X-750) wetted parts
QC: Hastelloy (C-276) wetted parts
TF: FM intrinsic safety label
TW: Russia Intrinsic Safety and Flameproof
Y ( ): Alternate pressure ports
Note:
Application of some available options may affect standard performance.