mv/V output, 0-100 thru 100K psi, Hazardous Location Approvals
870 employs a solid machined diaphragm sensor which provides a rugged and reliable solution with excellent repeatability and resistance to pressure spikes. 870 hazardous approval options include Intrinsically safe and Explosion proof for US, Canada and Atex.
Features
Many Options available
All Stainless Steel construction
IP-68 Rated
High Pressure Applications
Full Scale Pressure Range: 0-100 thru 0-100K PSIS (0-6.89 thru 0-6894 bar)
Accuracy (RSS):
- (BFSL Linearity, Hysteresis, Repeatability)
-
- 0-300 PSI thru 0-15K PSI Ranges (±0.20% FSO ( ±0.15% FSO improved with “DN” option))
- < 0-300 PSI or > 0-15K PSI Ranges (±0.25% FSO ( ±0.15% FSO improved with “DN” option))
- Linearity (Best Fit Straight Line):
-
- 0-300 PSI thru 0-15K PSI Ranges (±0.10% FSO (BFSL), Typical)
- < 0-300 PSI or > 0-15K PSI Ranges (±0.15% FSO (BFSL), Typical)
Hysteresis: < ± 0.05% FSO, Typical
Repeatability: < ± 0.05% FSO, Typical
Full Scale Output (FSO): 2 mV/V
Zero and Span Balance: ±1% FSO
Long Term Stability: ≤±0.25% FSO per 6 months
Response Time: <2 mSec to reach 90% FSO
Temperature Effect on Zero: ≤±1% FSO per 100°F (37°C)
Temperature Effect on Span: ≤±1% FSO per 100°F (37°C)
Compensated Temperature: 70°F to 170°F (21°C to 76°C)
Operating Temperature: -40°F to 190°F (-40°C to 87°C)
Storage Temperature Limit: -65°F to 250°F (-53°C to 121°C)
Supply Voltage: 10 Vdc nominal, 15 Vdc maximum
Power Supply Regulation Effect: Ratiometric
Output Signal: 2 mV/Volt (Nominal)
Bridge Impedance: 5000 Ohms nominal
Insulation Resistance: 1000 MegOhms to case ground at 50 Vdc and 70°F (21°C)
Electrical Connection: 1/2″ NPT (M), 18 AWG wire, 72″
Wire Color Codes:
Red +Power
Black +Signal
Green -Power
White – Signal
Pressure Connection:
- 0-50 thru 0-15K PSI (1/4″ – 18 NPT Female (0-3.3 thru 0-1034 bar))
- 0-20K thru 0-50K PSI (1/4″ F250-C High Pressure Tube (0-1378 thru 0-3447 bar))
- 0-60K thru 0-100K PSI (5/16″ F312C High Pressure Tube (0-4136) thru 0-6894 bar))
Proof Pressure:
- 0-100 thru 0-15K PSI (1.5 times FSPR or 20K PSI (1378 bar), (0-6.8 thru 0-1034 bar) whichever is less)
- 0-20K thru 0-100K PSI (1.2 times FSP (0-1378 thru 0-6894 bar))
Burst Pressure:
- 0-100 thru 0-15K PSI (≥ 2.3 to 5 times FSPR dependent on (0-6.8 thru 0-10342 bar) sensor)
- 0-20K thru 0-100K PSI (1.5 times FSPR or 125K PSI (8618 bar) (0-1378 thru 0-6894 bar) whichever is less)
Mounting: Supported by process piping or optional mounting bracket
Enclosure:
- 0-100 thru 0-15K PSI (15-5 PH and 316 stainless steel (0-6.8 thru 0-1034 bar))
- 0-20K thru 0-100K PSI (316 SST and PH 13-8 Mo SST (0-1378 thru 0-6894 bar))
Wetted Parts:
- 0-100 thru 0-15K PSI (15-5 PH stainless steel (0-6.8 thru 0-1034 bar))
- 0-20K thru 0-100K PSI (PH 13-8 Mo SST (0-1378 thru 0-6904 bar))
Shock Limitation: 100 G’s
Weight: 24 oz. (0.680 kilograms)
Identification: Laser etched onto body
Enclosure: Classification NEMA 4X
DF: Bleed port (10K PSI and below)
DG: Improved temperature compensation (<5%/100°F for zero/span)
DH: Special range
DN: Improved Accuracy (±0.15% FSO)
DQ: Cleaning for oxygen service
EA: Special calibration run
JJ: Direct mount indicator with explosion proof housing
JS: Direct mount indicator
ME: CSA explosion proof label
MR: Modified electrical damping
NG: ATEX flameproof label
NH: Customer specified identification
NJ: CE label
NK: ATEX intrinsic safety label
NX: CSA intrinsic safety label
NY: FM explosion proof label
NZ: FM nonincendive label
PW: 1/8 DIN digital indicator (consult factory)
QA: 316 stainless steel wetted parts
QB: Inconel (X-750) wetted parts
QC: Hastelloy (C-276) wetted parts
TF: FM intrinsic safety label
Y ( ): Alternate pressure ports
Note:
Application of some available options may affect standard performance.