0%

MODEL 870 PRESSURE TRANSMITTER

mv/V output, 0-100 thru 100K psi, Hazardous Location Approvals

870 employs a solid machined diaphragm sensor which provides a rugged and reliable solution with excellent repeatability and resistance to pressure spikes. 870 hazardous approval options include Intrinsically safe and Explosion proof for US, Canada and Atex.

Features

 Many Options available

 All Stainless Steel construction

 IP-68 Rated

 High Pressure Applications

Full Scale Pressure Range:  0-100 thru 0-100K PSIS (0-6.89 thru 0-6894 bar)

Accuracy (RSS):

  • (BFSL Linearity, Hysteresis, Repeatability)
    • 0-300 PSI thru 0-15K PSI Ranges  (±0.20% FSO ( ±0.15% FSO improved with “DN” option))
    • < 0-300 PSI or > 0-15K PSI Ranges  (±0.25% FSO ( ±0.15% FSO improved with “DN” option))
  • Linearity (Best Fit Straight Line):
    • 0-300 PSI thru 0-15K PSI Ranges  (±0.10% FSO (BFSL), Typical)
    • < 0-300 PSI or > 0-15K PSI Ranges  (±0.15% FSO (BFSL), Typical)

Hysteresis:  < ± 0.05% FSO, Typical

Repeatability:  < ± 0.05% FSO, Typical

Full Scale Output (FSO):  2 mV/V

Zero and Span Balance:  ±1% FSO

Long Term Stability:  ≤±0.25% FSO per 6 months

Response Time:  <2 mSec to reach 90% FSO

Temperature Effect on Zero:  ≤±1% FSO per 100°F (37°C)

Temperature Effect on Span:  ≤±1% FSO per 100°F (37°C)

Compensated Temperature:  70°F to 170°F (21°C to 76°C)

Operating Temperature:  -40°F to 190°F (-40°C to 87°C)

Storage Temperature Limit:  -65°F to 250°F (-53°C to 121°C)

Supply Voltage:  10 Vdc nominal, 15 Vdc maximum

Power Supply Regulation Effect:  Ratiometric

Output Signal:  2 mV/Volt (Nominal)

Bridge Impedance:  5000 Ohms nominal

Insulation Resistance:  1000 MegOhms to case ground at 50 Vdc and 70°F (21°C)

Electrical Connection:  1/2″ NPT (M), 18 AWG wire, 72″

Wire Color Codes:

Red                 +Power

Black              +Signal

Green              -Power

White             – Signal

Pressure Connection:

  • 0-50 thru 0-15K PSI  (1/4″ – 18 NPT Female (0-3.3 thru 0-1034 bar))
  • 0-20K thru 0-50K PSI  (1/4″ F250-C High Pressure Tube (0-1378 thru 0-3447 bar))
  • 0-60K thru 0-100K PSI  (5/16″ F312C High Pressure Tube (0-4136) thru 0-6894 bar))

Proof Pressure:

  • 0-100 thru 0-15K PSI  (1.5 times FSPR or 20K PSI (1378 bar), (0-6.8 thru 0-1034 bar) whichever is less)
  • 0-20K thru 0-100K PSI  (1.2 times FSP (0-1378 thru 0-6894 bar))

Burst Pressure:

  • 0-100 thru 0-15K PSI  (≥ 2.3 to 5 times FSPR dependent on (0-6.8 thru 0-10342 bar) sensor)
  • 0-20K thru 0-100K PSI  (1.5 times FSPR or 125K PSI (8618 bar) (0-1378 thru 0-6894 bar) whichever is less)

Mounting:  Supported by process piping or optional mounting bracket

Enclosure:

  • 0-100 thru 0-15K PSI  (15-5 PH and 316 stainless steel (0-6.8 thru 0-1034 bar))
  • 0-20K thru 0-100K PSI  (316 SST and PH 13-8 Mo SST (0-1378 thru 0-6894 bar))

Wetted Parts:

  • 0-100 thru 0-15K PSI  (15-5 PH stainless steel (0-6.8 thru 0-1034 bar))
  • 0-20K thru 0-100K PSI  (PH 13-8 Mo SST (0-1378 thru 0-6904 bar))

Shock Limitation:  100 G’s

Weight:  24 oz. (0.680 kilograms)

Identification:  Laser etched onto body

Enclosure:  Classification NEMA 4X

DF:  Bleed port (10K PSI and below)

DG:  Improved temperature compensation (<5%/100°F for zero/span)

DH:  Special range

DN:  Improved Accuracy (±0.15% FSO)

DQ:  Cleaning for oxygen service

EA:  Special calibration run

JJ:  Direct mount indicator with explosion proof housing

JS:  Direct mount indicator

ME:  CSA explosion proof label

MR:  Modified electrical damping

NG:  ATEX flameproof label

NH:  Customer specified identification

NJ:  CE label

NK:  ATEX intrinsic safety label

NX:  CSA intrinsic safety label

NY:  FM explosion proof label

NZ:  FM nonincendive label

PW:  1/8 DIN digital indicator (consult factory)

QA:  316 stainless steel wetted parts

QB:  Inconel (X-750) wetted parts

QC:  Hastelloy (C-276) wetted parts

TF:  FM intrinsic safety label

Y ( ):  Alternate pressure ports

Note:

Application of some available options may affect standard performance.