0-5 Vdc output, 2″ 1502 Fitting, Hazardous Location Approvals
709 is a 0-5Vdc output hammer union transmitter to monitor pump pressures in oil servicing applications like drilling, cementing, and hydrofracturing. Available with hazardous location approvals and a variety of electrical connections.
Features
1502 Hammer Union Pressure Fitting
ShuntCal
High-Pressure Applications
Full Scale Pressure Range: 0-5K, 10K, 15K, 20K PSIG (0-345, 689, 1034, 1379 bar)
Combined Accuracy (BFSL): (Non-Linearity, Hysteresis & Repeatability) ≤± 0.25% FSO
Full Scale Output (FSO): 5 Vdc ±1% FSO
Zero Balance: 0 Vdc ±1% FSO
Long-Term Stability: ≤±0.25% FSO per 6 months
Response Time: ≤2.5 mSec to reach 90% of FSO
Compensated Temperature: -20°F to 185°F (-29°C to 85°C)
Operating Temperature: -40°F to 250°F (-40°C to 121°C)
Storage Temperature Limits: -67°F to 302°F (-55°C to 150°C)
Temperature Effect on Zero: ≤±1% FSO per 100°F (37°C)
Temperature Effect on Span: ≤±1% FSO per 100°F (37°C)
Supply Voltage: 9-30 Vdc (10.5 to 28 Vdc w/approval)
Power Supply Regulation Effect (Calibrated at 12 Vdc): ≤±0.01% FSO per Volt
Output Signal: 0 – 5 Volts at 70°F (21°C)
Current Draw: 7.5 mA
Load Impedance: 410K Ohms minimum
Range Calibration Signal: 100% of FSPR
Calibration Power: Short pins E & F
Calibration Signal Accuracy: ≤±0.2% FSO. The exact signal to pressure correlation is provided with each unit
Circuit Protection: Varistor protected across the input leads for surges above 1000V at 50 microseconds
Bridge Resistance: 10K Ohms nominal
Insulation Resistance: ≥100 MegOhms to case ground
Electrical Connection: Mates with Bendix P/N PT06E-10-6S or equivalent
PIN OUTS:
NOTE:
Pressure Connection: Male hammer union 2 inch #1502
Pressure Cavity Volume: 0.4 cubic inches
- 1.67 times the FS or 22.5K PSI (1550 bar) for union #1502
- 30K PSI (2068 bar) for union #2002 whichever is less
Enclosure Materials: 304 stainless steel
Wetted Materials: Inconel X-750, heat treated per MR0175-2000
Shock Limitation: 100 G’s
Weight: 5.5 lbs nominal (2.4 kg)
Identification: Laser etched onto body
Enclosure Classification: NEMA 4X
DH: Special range
EA: Special calibration run
NJ: CE label
NX: CSA Intrinsic Safety label
TF: FM Intrinsic Safety label
TP: Low cavity volume sensor design
TW: Russia Intrinsic Safety
ZQ: CG379-C-145-2P (Glenair) electrical connector
ZT: REC-M-10TP-N-04-16 (Jupiter) connector