0%

MODEL 59T LEVEL AND TEMPERATURE TRANSMITTER

Integral Temperature Sensor, 0-40″wc thru 835’wc, PUR Cable Standard, Stainless Steel Sensor and Housing

The Model 59T is a dual output Temperature and Level Transmitter able to measure temperatures up to 158°F. A higher accuracy option is available to .25%. PVC and FEP cables are also available. A complete range of accessories for use in level applications are available, many from stock

Features

 IP-68 Rated

All Stainless Steel construction

 RoHS Compliant

Low Pressure Applications

  • The Model 59T dual output Temperature/Level Transmitter measures temperatures as low as 32°F thru 158°F.Polyurethane cable is standard.

    Different cable materials and o rings are available.

    Use it to measure Liquid Level and Depth for Water and Waste Water applications, Lift Stations, Reservoirs and Dams, Rivers, Holding Ponds, Wells, In-ground/Above Ground Tanks and with Inventory Tank Gauging.

    Ranges from 0-40″WC thru 15 ‘WC have combined accuracy of +/- .50% FSO

    Ranges greater than 15′ WC have combined accuracy of +/- .35% FSO

    An improved accuracy on ranges >15’ is available at 0.25% FSO.

    Viatran also offers a complete range of accessories for use in level applications such as a surge protector, cable hangers and weights, meters and junction boxes.

Pressure Ranges:  0-50, 100 Inches Water Column, 0-2, 3, 5 PSI

Combined Accuracy (Non-Linearity, Hysteresis, Repeatability):  ≤±0.50% FSO for ranges < 15 Ft. W.C.

Compensated Temperature Range:  32° to 158° F (0 to 70° C)

Operating Temperature Range:  14° to 158° F (-10 to 70° C)  **Note: Medium must not freeze near sensor

Storage Temperature Range:  -13° to 158° F (-25 to 70° C)

Long Term Stability (%FSO):  ≤±0.1% FSO / year at reference conditions

Thermal Effect on Zero:  ≤±0.8% FSO per 100° F

Thermal Effect on Span:  ≤±0.8% FSO per 100° F

Temperature Accuracy:  ≤±1.8° F (1°C)

Output Signal:  4-20 mA (for both the Pressure & Temperature)

Supply Voltage:  10 -30 Vdc (for both the Pressure & Temperature)

Power Supply Regulation:  <±005% FSO per volt

Circuit Protection:  Reverse polarity protected, CE marked

RFI/EMI:  CE EMC compliant as per IEC EN 61326

Voltage Spike Protection:  Withstand 1000 volt spike per EN 61000

Response Time:  <10mSec

Pressure Connection:  Protective POM cap

Ingress Protection:  IP 68

Overpressure Limit:  4x Minimum

Burst Pressure:  6x Minimum

Weight:  0.5 lbs. (without cable)

Housing:  316L stainless steel

Sensor Diaphragm:  316L stainless steel

O-ring Seals:  FKM

Protective Cap:  POM (Polyoxymethylene)

EA:  Special Calibration Run

PW:  Calibrate item with meter/display