0-32″ thru 0-335′ WC, Stainless Steel Housing, Ceramic Sensor, RapidShip
The Viatran Model 596 DLT Sensor Head is available in
ranges that can be set from 0-32 Inches W.C. to 0-335 Feet W.C. or equivalent in Meters or PSI by Viatran at the time of manufacturing This capability allows Viatran to rapidly ship the replacement Sensor Head within one or two days. No need for you to carry excess inventory.
Features
Detachable
IP-68 Rated
RoHS Compliant
- When you need to replace your wastewater level transmitter, you don’t have time to wait. Downtime is not an option.With Viatran’s new RapidShip program, the Model 596 Detachable Sensor Head is available in as little as one 1 to 2 days, and in some cases can be shipped overnight.
The RapidShip program allows you to reduce your inventory costs, minimize your supply chain management effort, eradicate unexpected delays and/or line down situations resulting from peaks in demand.
The Detachable Level Transmitter allows for a quick swap of the sensor head without having to remove your entire cable run.
Model 596 is a rugged transmitter that is ideal for higher viscosity media and is resistant to a wide variety of materials. Its semi-flush ceramic sensing face resists clogging and is easily cleaned, allowing it to be used without a cage.
This model can operate in pressure ranges from 0-32 in. w.c. to 0-335 ft. w.c. (or equivilent in meters or PSI )and an operating temperature range of -13° to 185° F (-25° to 85° C).
Viatran also stocks six of the most popular polyurethane cable sizes in lengths up to 150 feet (46 meters).
When ordering, please specify the range (depth) and cable length needed.
Standard Pressure Range: 0-32″ W.C. to 0-335 Feet W.C. or equivalent in Meters or PSI.
Accuracy: ≤ +/-0.1% FSO [Combined Non-Linearity (BFSL), Hysteresis & Repeatability]
Compensated Temperature Range: -4° to 176° F (-20 to 80° C)
Operating Temperature Range: -13° to 185° F (-25 to 85° C) **Note: Medium must not freeze near sensor
Storage Temperature Range: -13° to 185° F (-25 to 85° C)
Long Term Stability (%FSO): ≤ +/- 0.1% FSO / year **Note: At reference conditions
Thermal Effect on Zero: ≤ +/- 0.16% FSO per 100° F
Thermal Effect on Span: ≤ +/- 0.16% FSO per 100° F
Output Signal: 4-20 mA
Supply Voltage: 12-36 Vdc
Power Supply Regulation: < +/- .005% FSO per volt
Circuit Protection: Reverse polarity protected, CE marked
RFI / EMI: CE EMC compliant as per IEC EN 61326
Voltage Spike Protection: Withstand 1000 volt spike per EN 61000
Response Time: < 380 mSec
Pressure Connection: Removable Protective POM cap
Ingress Protection: IP 68
Overpressure Limit: 5x Minimum (≥ 167 Ft. range = 3.5x)
Weight: 1.4 lbs. (without cable)
Housing: 316L Stainless Steel
Sensor Diaphragm: Ceramic Al2O3 96%
O-ring Seals: FKM (Standard) or EPDM (Optional)
Removable Protective Cap: POM (Polyoxymethylene)
EA: Special Calibration Run
NSR: Non-Standard Range
PW: Calibrate Transmitter with Meter / Display
ZB: 1/2″ NPT Conduit Adapter