0%

MODEL 595 DETACHABLE LEVEL TRANSMITTER

0-16″ thru 335′ WC, PUR Cable Standard, PVC Housing, Ceramic Sensor, Lowest Level Rating

The Model 595 allows for a quick sensor swap without the removal of the installed polyurethane standard cable. PVC or FEP cables are also available. Sensor head and/or cable can be ordered separately. A complete range of accessories for use in level applications are available, many from stock.

Features

 IP-68 Rated

Detachable

 RoHS Compliant

Low Pressure Applications

  • The Model 595 Detachable Level Transmitter allows for a quick sensor swap without the removal of the installed cable. No special tools are required.Simply pull up the sensor, twist the sensor coupling sleeve till it is no longer engaged and then simply separate the two halves.595 is constructed of a PVC housing and ceramic sensor module, with a polyurethane cable as standard.

    Different cable materials and o rings are available.

    Use it to measure Liquid Level and Depth in applications where resistance to caustic materials is required.

    Semi flush ceramic sensor aids to reduce clogging if media contains solid materials.

    Viatran also offers a complete range of accessories for use in level applications such as a surge protector, cable hangers and weights, meters and junction boxes.

    Replacement sensor heads and/or cables can be purchased separately

Pressure Ranges:  0 – 16″ W.C. up to 0 – 335 Ft W.C. (Or equivalent in Meters or PSI)

Accuracy [Combined Non-Linearity (BFSL), Hysteresis & Repeatability]:

  • ≤ +/-0.35% FSO (Standard)
  • ≤ +/-0.25% FSO (Optional)

Compensated Temperature Range:  32° to 122° F (0 to 50° C)

Operating Temperature Range:  14° to 122° F (-10 to 50° C)  **Note: Medium must not freeze near sensor

Storage Temperature Range: 14° to 122° F (-10 to 50° C)

Long Term Stability (%FSO):  ≤ +/- 0.1% FSO / year ( At reference conditions)

Thermal Effect on Zero:  ≤ +/- 0.1% FSO per 100° F

Thermal Effect on Span:  ≤ +/- 0.1% FSO per 100° F

Output Signal:  4 – 20 mA

Supply Voltage:  10 – 32 Vdc

Power Supply Regulation:  < +/- .005% FSO per volt

Circuit Protection:  Reverse polarity protected, CE marked

RFI / EMI:  CE EMC compliant as per IEC EN 61326

Voltage Spike Protection:  Withstand 1000 volt spike per EN 61000

Response Time:  ≤ 380 mSec

Pressure Connection:  Open Face

Ingress Protection:  IP 68

Overpressure Limit:  6x Minimum (≥ 134 Ft. range = 3.2x)

Weight:  0.9 lbs. (without cable)

Housing:  PVC

Sensor Diaphragm:  Ceramic

O-ring Seals:  FKM (Standard) or EPDM (Optional)

DV:  SharkCage Removable Protective Cage

EA:  Special Calibration Run

PW:  Calibrate Transmitter with Meter / Display