0%

MODEL 590 DETACHABLE LEVEL TRANSMITTER

0-40″ thru 835′ WC, PUR Cable Standard, Stainless Steel Sensor and Housing

The Model 590 Detachable Level Transmitter allows for a quick sensor swap without the removal of the installed polyurethane standard cable. PVC and FEP cables are also available. 590/591 have the deepest level rating at 835′. Sensor head and/or cable can be ordered separately. A complete range of accessories for use in level applications are available, many from stock.

Features

Detachable

All Stainless Steel construction

 IP-68 Rated

Low Pressure Applications

RoHS Compliant

 

The Model 590 Detachable Level Transmitter allows for a quick sensor swap without the removal of the installed cable.

No special tools are required. Simply pull up the sensor, twist the sensor coupling sleeve till it is no longer engaged and then simply separate the two halves.

590 is constructed of stainless steel housing and sensor module, with a polyurethane cable as standard.

Different cable materials and o rings are available.

Use it to measure Liquid Level and Depth for Water and Waste Water applications, at Lift Stations, Reservoirs and Dams, Rivers, Holding Ponds, Wells, In-ground/Above Ground Tanks and with Inventory Tank Gauging.

Ranges from 0-40″WC thru 15 ‘WC have combined accuracy of +/- .50% FSO

Ranges greater than 15’ WC have combined accuracy of +/- .35% FSO

Viatran also offers a complete range of accessories for use in level applications such as a surge protector, cable hangers and weights, meters and junction boxes.

Replacement sensor heads and/or cables can be purchased separately

Pressure Ranges:  0 – 40″ W.C. up to 0 – 835 Ft W.C. (Or equivalent in Meters or PSI)

Accuracy [Combined Non-Linearity (BFSL), Hysteresis & Repeatability]:

  • For ranges ≥ 15 Ft. W.C. (≤ +/-0.35% FSO)
  • For ranges < 15 Ft. W.C. (≤ +/- 0.50% FSO)

Compensated Temperature Range:  32° to 158° F (0 to 70° C)

Operating Temperature Range:  -4° to 158° F (-20 to 70° C)  *Note: Medium must not freeze near sensor

Storage Temperature Range:  -13° to 158° F (-25 to 70° C)

Long Term Stability (%FSO):  ≤ +/- 0.1% FSO / year (At reference conditions)

Thermal Effect on Zero:  ≤ +/- 0.8% FSO per 100° F

Thermal Effect on Span:  ≤ +/- 0.8% FSO per 100° F

Output Signal:  4-20 mA

Supply Voltage:  8 -32 Vdc

Power Supply Regulation:  < +/- .005% FSO per volt

Circuit Protection:  Reverse polarity protected, CE marked

RFI / EMI:  CE EMC compliant as per IEC EN 61326

Voltage Spike Protection:  Withstand 1000 volt spike per EN 61000

Response Time:  <10 mSec

Pressure Connection:  Protective POM cap

Ingress Protection:  IP 68

Overpressure Limit:  4x Minimum (>525 Ft. range = 3.2x)

Burst Pressure:  5x Minimum (> 525 Ft. range = 4.8x)

Weight:  0.9 lbs. (without cable)

Housing:  316L stainless steel

Sensor Diaphragm:  316L stainless steel

O-ring Seals:  FKM (Standard) or EPDM (Optional)

Protective Cap:  POM (Polyoxymethylene)

EA:  Special Calibration Run

PW:  Calibrate Transmitter with Meter / Display

ZB:  1/2″ NPT Conduit Adapter