Integral Shutoff for inline installation, Slurry and Sludge measurement
Designed for harsh abrasive slurry, the 555 has a unique feature which allows for wet installation in less than an hour through the use of a pipe saddle with integral shutoff. External adjustments and corrosive resistant wetted materials make this an excellent choice for pulp and paper, wastewater processing, slurry and sludge measurements.
Features
ShuntCal
All Stainless Steel construction
Full Scale Pressure Range (FSPR): 0-50, 100, 150, 200, 250, 300, 500, PSIS
Combined Accuracy (Non-Linearity, Hysteresis and repeatability):
- 50 – 100 PSI≤±.5% FSO
- 150 – 500 PSI≤±.3% FSO
Full Scale Output (FSO): 16 mA at 70°F (21°C)
Resolution: Infinite
Long Term Stability: ≤±0.5% FSO per 6 months
Pressure Connection Effect Zero Balance: ≤±1% FSO
Response Time (Mechanical & Eletrical Combined): <20 mSec to reach 90% of Full Scale
Temperature Effect on Zero: ±1% FSO per 100°F (37°C)
Temperature Effect on Span: ±1% FSO per 100°F (37°C)
Combined at 4:1 Range Down: ≤±4.0% FSO per 100°F (37°C)
Compensated Temperature Range: 70°F to 170°F (21°C to 77°C)
Maximum Operating Temperature:
- 185°F (85°C) – Ambient
- 250°F (121°C) – Fluid
Minimum Operating Temperature: -40°F (-40°C)
Storage Temperature Limits: -65°F to 250°F (-53°C to 121°C)
Supply Voltage: 12 to 30 Vdc
Power Consumption: ≤±0.02% FSO per volt
Output Signal: 4-20 mA at 70°F (21°C)
Load Impedance: 900 Ohms maximum at 30 Vdc
Elevation: -100% of FSO
Suppression: +50% of FSO
Span Adjustment: Rangeable down 4:1 from standard range
Range Calibration Signal: 20% of FSPR externally switched
Calibration Signal Accuracy: ±1.0% FSO. The exact signal to pressure correlation is provided with each unit
Circuit Protection: Varistor protected across the input leads for surges above 40V and currents to 250 Amps Peak with a pulse width of 20 µSec. Reverse polarity protected
Bridge Resistance: 5K Ohms nominal
Insulation Resistance: ≥200 MegOhms to case ground (≤5 nS)
RFI/EMI: Negligible to 500 MHz at 5 Watts direct contact
Electrical Connection: 1/2” NPT (M), 18 AWG, 72”
Wire Color Codes:
Red +Power/Signal
Black -Power/Signal
Green Case Ground
Pressure Connection: 100 – 1000 PSI Flush Diaphragm
Proof Pressure: 1.5 times URL
Burst Pressure: ≥ 3 times rated URL
Shock Limitation: 100 g’s
Weight: 70 oz (2kg)
Enclosure Materials: Inconel X750 and 316L stainless steel
Wetted Materials: Inconel X750 and 316L stainless steel
Enclosure Classification: NEMA/Type 4X (1P68)
FM:
- Intrinsic Safety: Class I, II, III, Division 1, Groups A-G, and AEx ia IIC, T4 at Ta=80ºC, T5 at Ta=40ºC, Indoor and Outdoor NEMA/Type 4X Hazardous Locations
- Nonincendive: Class I,II,III Div. 2, Groups A-G and Class I, Zone 2, Group IIC, T4 at Ta=80ºC, T5 at Ta=40ºC
CSA (Pending):
- Intrinsic Safety: Class I, Div. 1, A-D Class II, E-G, Class III, Ex ia IIC T4 at Ta=80ºC, T5 at Ta=40ºC
ATEX:
- Intrinsic Safety: II 1 G EEx ia IIC, -20ºC T4, Ta 50ºC
CE:
- EMC Directive 89/336/EEC and Low Voltage Directive 72/23/EEC
- EN 61010-101993/A2:1995: Low Voltage Standard
- EN 61326: EMC Conformity Standard
- PED Directive 97/23/EC EMC Directive 89/336/EEC
BB: Mini change electrical connector
BP: Micro change electrical connector
CL: Extra lead length (6 ft standard)
DG: Improved temperature and compensation
DK: Special shunt calibration
EA: Special calibration run
NG: ATEX Flameproof label
NH: Customer specified identification
NJ: CE label
NK: ATEX Intrinsic Safety label
NSR: Non standard range
NX: CSA Intrinsic Safety label
NZ: FM Nonincendive label
TF: FM Intrinsic Safety label
TJ: CSA Div / Zone 2
TW: Russia Intrinsic Safety
VD: G2” retaining nut
Z (): Alternate electrical connection
ZU: irect coupled cable
- Pipe Saddle with shutoff
- Conduit connection box
- Calibration text fixture