0%

MODEL 551 PRESSURE TRANSMITTER

Flush Mount Sensor, 0-50 thru 1000 psi, Solid Machined Diaphragm, Sealed External Adjustments

551 is designed to provide rugged performance while measuring harsh corrosive materials. The sensor is a stainless steel machined diaphragm, with no oil fill. The zero cavity flush sensor provides an easy clean surface with no clogging. Magnetically coupled external adjustments prevent fluid ingress while providing a rangeable, field adjustable solution.

Features

 All Stainless Steel construction

Full Scale Pressure Range (FSPR):  0-50, 100, 150, 200, 250, 300, 500, 750, 1000, PSIG, PSIS, PSiA

Combined Linearity, Hysteresis and Repeatability:  ≤±0.45%

Full Scale Output (FSO):  16 mA at ±0.5% FSO

Resolution:  Infinite

Long Term Stability:  ≤±0.5% FSO

Pressure Connection Effect Zero Balance:  ≤±0.5% FSO

Mechanical & Electrical Combined:  ≤0.1mSec

Temperature Effect on Zero:  ≤± 2% FSO per 100°F (37°C)

Temperature Effect on Span:  ≤± 2% FSO per 100°F (37°C)

Compensated Temperature Range:  0°F to 185°F (-17°C to 85°C)

Operating Temperature Range:

  • -40°F to 250°F (-40°C to 121°C) -Process
  • -40°F to 185°F (-40°C to 85°C) -Ambient

Storage Temperature:  -40°F to 250°F (-40°C to 121°C)

Sensor Technology:  Bonded foil strain gage

Supply Voltage:  12 to 30 Vdc

Power Supply Regulation:  ≤±0.04% FSO per Volt

Output Signal:  4 – 20 mA at 70°F (21°C)

Load Impedance:  1400 Ohms max at 40 Vdc

Ripple:  ≤1% FSO

Zero Balance:  4 mA ±0.5% FSO

Zero Adjustment:  -50% FSPR (elevation) to 100% FSPR (suppression). Coarse and fine adjustments standard

Span Adjustment:  5:1 turndown, externally

Range Calibration Signal:  20% ±1% of FSPR, externally switched. The exact signal to pressure correlation is provided with each unit.

Circuit Protection:  Varistor protected across the input leads for surges above 38 V and currents to 250 Amps peak with a pulse width of 8-20 µSec. Reverse polarity protected

Bridge Resistance:  5000 Ohms nominal

Insulation Resistance:  ≥ 2000 MegOhms at 50 Vdc

RFI/EMI Suppression:  ≤1% FSO output change at 30 V/meter, 10-1000 Mhz

Electrical Connection:  1/2” NPT male conduit, 3 wires, 18 AWG, 36”L

Wire Color Codes:

Red             + Power/Signal

Black           – Power/Signal

Green            Case Ground

Pressure Connection:  M44 X 1.25 fitting

Proof Pressure:  1.5 times rated range

Burst Pressure:  ≥ 3 times rated range or max range of clamp and tubing, whichever is less

Weight:  22 oz

Enclosure Materials:  304 and 316 stainless steel

Wetted Materials:  17-4PH NACE (Inconel X750 optional)

Identification:  Laser etched onto bod

Measured Fluids:  Any gas or liquid compatible with 17-4PH NACE

Enclosure Classification:  NEMA 4X, 5, 6, 12

Alternate Connectors:

BZ:  Micro change connector

ZP:  6-pin hermetic (Bendix style)

Performance Options:

DG:  Improved temperature compensation

DH:  Special range (550 only)

EA:  Special calibration

JJ:  Direct mount indicator with Explosion Proof housing

JS:  Direct mount indicator

NH:  Customer specified identification

PW:  1/8 DIN digital indicator

QB:  Inconel wetted parts

TW:  Russia Intrinsic Safety

  • Conduit Connection Box
  • Tank Fittings
  • Gylon Sealing Gasket

Note:

Application of some available options may affect standard performance.