MODEL 544 PRESSURE TRANSMITTER

4-20 mA, 5″ WC to 100 psi, Hazardous approvals

Viatran’s Model 544 is a low pressure gage transmitter designed for precise measurement in hazardous locations. External adjustments allow for field calibration and ranging to provide measurement flexibility.

Features

 High Accuracy

 Many Options available

The 544 features a special internal calibration signal that allows users to calibrate the transmitter without an external pressure source.

The 544 provides a 4 to 20 mA output signal measuring pressures from 0 to 5″ WC thru 0-100 PSIG.

External zero, span, and calibration controls are hermetically sealed for protection against harsh environments.

These controls are externally adjustable with Viatran’s unique magnetically coupled drive system.

Model 544 also has a signal conditioner that allows for 5:1 ranging of the transmitter’s standard pressure range (FSPR).

Designed to meet intrinsically safe standards, the 544 provides reliable and safe pressure measurement in harsh process applications.

Full Scale Pressure Ranges:

  • 0-5, 10, 20, 50, 100, 300, 750″ W.C.G
  • 0-15, 50, 100 PSIG
  • 0-15 PSIV

Nonlinearity (Best Fit Straight Line):  ≤±0.15% FSO

Hysteresis & Repeatability:  ≤±0.10% FSO

Full Scale Output (FSO):  16 mA at 70° F

Long Term Stability:  ≤±0.2% FSO per 6 months

Compensated Temperature Range:  70°F to 170°F (21°C to 76°C)

Operating Temperature Range:

  • 5″WC to 50″WC (0° F to +170° F)
  • 100″WC to 100 PSI (-40° F to +170° F)

Storage Temperature Limits:

  • 5″WC to 50″WC (0° F to +170° F)
  • 100″WC to 100 PSI (-40° F to +170° F)

Temperature Effect on Zero:  <± 1.0% FSO per 100° F

Temperature Effect on Span:  <± 1.0% FSO per 100° F

Supply Voltage:  10 to 40 Vdc

Power Supply Regulation:  ±0.02% FSO per volt

Output Signal:  4-20 mA at 70° F

Load Impedance:  1500 Ohms maximum at 40 Vdc

Zero Adjustment:

  • Elevation:  -100% of FSO
  • Suppression:  +50% of FSO

Span Adjustment:  Rangeable down 5:1 from standard range

Calibration Signal:  20% of FSPR, externally switched

Calibration Signal Accuracy:  The exact signal to pressure correlation is provided with each unit

Circuit Protection:

  • Varistor protected across the input leads for surges above 40V and currents to 250 Amps peak with a pulse width of 8×20 µ Sec.
  • Reverse polarity protected

Insulation Resistance:  < 5 nS

RFI / EMI Suppression:  <1.0% FSO from 0 to 15 MHz at 2V peak to peak direct contact

Electrical Connections:  1/2″ NPT Male, 3 Wires, 18 AWG, 36″

Connection Color Codes:

Red                + Power / Signal

Black             – Power / Signal

Green              Case Ground

Wetted Parts:  316 Stainless steel

Housing:  316 Stainless Steel with a Cadmium plated electrical connector

Weight:  3.5 lbs. nominal

Identification:  Laser etched onto body

Pressure Connection:  1/4″ – 18 NPT female

Proof Pressure:  500 PSI

Burst Pressure:  1000 PSI

Shock Limitation:  5 Gs

Fill Fluid:  Silicone oil

Enclosure Classification:  NEMA 4X

Mounting:  May be supported by process piping or by optional mounting bracket

PERFORMANCE OPTIONS:

DK:  Special shunt calibration setting

DQ:  Cleaning for oxygen service

EA:  Special calibration run

GE:  Buna-N “O”-Ring

JJ:  Direct mount indicator w/ explosion proof housing

JS:  Direct mount indicator

MD:  FM label

NF:  Fast response time

NH:  Customer specified identification

PW:  1/8 DIN digital indicator

ALTERNATE PRESSURE PORTS:

YA:  MS 33649-04

YH:  1/8 NPT(M)

YI:  1/8 NPT(F)

YK:  1/4 NPT(M)

YN:  3/8 NPT(F)

Note:

Application of some available options may affect standard performance.