0%

MODEL 376 PRESSURE TRANSMITTER

Low Range Differential Pressure, Compact Size

To accommodate vigorous test applications, the 376has a static line pressure rating and standard overpressure of 500 PSI (34 bar). With a response time as low as 6 milliseconds (depending on range), the 376 is one of the fastest differential units on the market.

Features

High Accuracy

Many Option Available

Low Pressure Applications

Viatran’s proprietary technology provides an accuracy of better than ±0.15% FSO. Wetted surfaces are manufactured from 316 stainless steel allowing for better corrosion resistance. Viatran designed the “76” Series to be easily accessible in confined spaces. The X76 is supported by the process connection or by an adaptable L-shaped mounting bracket.

A quick disconnect electrical connection allows for easy setup and removal. Topmounted zero and span adjustments and an internal calibration circuit simplify field setup and provide a quick two-point calibration check.

With over twenty different electrical connections and pressure ports, as well as optional improved temperature performance and modified outputs, the 376 exceeds the most demanding application requirements.

Full Scale Pressure Ranges:

  • 0-5, 10, 20, 50, 100, 300, 750″ W.C.D.
  • 0-15, 50, 100 PSID (0-1, 3.4, 6.8 bar)

Nonlinearity (Best Fit Straight Line):  ≤±0.15% FSO

Hysteresis:  ≤±0.10% FSO

Repeatability:  ≤ ±0.10% FSO

Full Scale Output (FSO):  16 mA

Resolution:  Infinite

Long Term Stability:  ≤±0.2% FSO per 6 months

Pressure Connection Effect Zero Balance:  ≤±1% FSO

Compensated Temperature Range:  70°F to 170°F (21°C to 77°C)

Operating Temperature Range:

  • 5″WC to 50″WC (0° F to +170° F)
  • 100″WC to 100 PSI (-40° F to +170° F)

Storage Temperature Limits:

  • 5″WC to 50″WC (0° F to +170° F)
  • 100″WC to 100 PSI (-40° F to +170° F)

Temperature Effect on Zero:  ≤± 2.0% FSO per 100° F

Temperature Effect on Span:  ≤± 2.0% FSO per 100° F

Supply Voltage:  10 to 45 Vdc

Power Supply Regulation:  ≤±0.10% FSO change over supply voltage range

Output Signal:  4 to 20 mA

Zero Adjustment:  ± 10 % FSO min. / ±20% FSO max.

Span Adjustment:  ± 10% FSO min. / ±20% FSO max.

Calibration Signal:  80% FSO

Calibration Signal Accuracy:  ≤±0.2% FSO

Circuit Protection:  Reverse polarity protected

Insulation Resistance:  200 MegOhms

Electrical Connection:  Bendix PT02E-10-6P, mates PT06E-10-6S (SR)

Pin Outs:

Pin A               + Power / Signal

Pin B                – Power / Signal

Pin C                  Calibrate

Pin D                  Calibrate

Pin E                  No Connection

Pin F                  No Connection

Pressure Connection:  1/4″ – 18 NPT female

Line Pressure:  500 PSI (34 bar)

Proof Pressure:  500 PSI (34 bar)

Burst Pressure:  1000 PSI (68.9 bar)

Pressure Cavity Volume:  Approximately 2 mL each side

Volume Displacement at FSPR:  Approximately 0.1 mL

Fill Fluid:  Approximately 1.5 mL

Mounting:  May be supported by process piping or by optional mounting bracket

Mounting Position Effect:  <1″ WC, any direction

Weight:  2 lbs

Wetted Materials: 316 Stainless steel

Housing:  Powder coated cast alloy

Identification:  Laser etched onto body

ELECTRICAL CONNECTION:

B ( ):  Alternate electrical connector

ALTERNATE PRESSURE PORTS:

Y ( ):  Alternate pressure ports

PERFORMANCE OPTIONS:

DG:  Improved temperature compensation to ±1.0% FSO per 100°F

DH:  Special ranging

DK:  Special shunt calibration setting

DM:  Modified full scale output

EA:  Special calibration run

NH:  Customer specified identification

PW:  1/8 DIN digital indicator

Note:

Application of some available options may affect standard performance.