Low Range Differential Pressure, Compact Size
To accommodate vigorous test applications, the 376has a static line pressure rating and standard overpressure of 500 PSI (34 bar). With a response time as low as 6 milliseconds (depending on range), the 376 is one of the fastest differential units on the market.
Features
High Accuracy
Many Option Available
Pressure Applications
Viatran’s proprietary technology provides an accuracy of better than ±0.15% FSO. Wetted surfaces are manufactured from 316 stainless steel allowing for better corrosion resistance. Viatran designed the “76” Series to be easily accessible in confined spaces. The X76 is supported by the process connection or by an adaptable L-shaped mounting bracket.
A quick disconnect electrical connection allows for easy setup and removal. Topmounted zero and span adjustments and an internal calibration circuit simplify field setup and provide a quick two-point calibration check.
With over twenty different electrical connections and pressure ports, as well as optional improved temperature performance and modified outputs, the 376 exceeds the most demanding application requirements.
Full Scale Pressure Ranges:
- 0-5, 10, 20, 50, 100, 300, 750″ W.C.D.
- 0-15, 50, 100 PSID (0-1, 3.4, 6.8 bar)
Nonlinearity (Best Fit Straight Line): ≤±0.15% FSO
Hysteresis: ≤±0.10% FSO
Repeatability: ≤ ±0.10% FSO
Full Scale Output (FSO): 16 mA
Resolution: Infinite
Long Term Stability: ≤±0.2% FSO per 6 months
Pressure Connection Effect Zero Balance: ≤±1% FSO
Compensated Temperature Range: 70°F to 170°F (21°C to 77°C)
Operating Temperature Range:
- 5″WC to 50″WC (0° F to +170° F)
- 100″WC to 100 PSI (-40° F to +170° F)
Storage Temperature Limits:
- 5″WC to 50″WC (0° F to +170° F)
- 100″WC to 100 PSI (-40° F to +170° F)
Temperature Effect on Zero: ≤± 2.0% FSO per 100° F
Temperature Effect on Span: ≤± 2.0% FSO per 100° F
Supply Voltage: 10 to 45 Vdc
Power Supply Regulation: ≤±0.10% FSO change over supply voltage range
Output Signal: 4 to 20 mA
Zero Adjustment: ± 10 % FSO min. / ±20% FSO max.
Span Adjustment: ± 10% FSO min. / ±20% FSO max.
Calibration Signal: 80% FSO
Calibration Signal Accuracy: ≤±0.2% FSO
Circuit Protection: Reverse polarity protected
Insulation Resistance: 200 MegOhms
Electrical Connection: Bendix PT02E-10-6P, mates PT06E-10-6S (SR)
Pin Outs:
Pin A + Power / Signal
Pin B – Power / Signal
Pin C Calibrate
Pin D Calibrate
Pin E No Connection
Pin F No Connection
Pressure Connection: 1/4″ – 18 NPT female
Line Pressure: 500 PSI (34 bar)
Proof Pressure: 500 PSI (34 bar)
Burst Pressure: 1000 PSI (68.9 bar)
Pressure Cavity Volume: Approximately 2 mL each side
Volume Displacement at FSPR: Approximately 0.1 mL
Fill Fluid: Approximately 1.5 mL
Mounting: May be supported by process piping or by optional mounting bracket
Mounting Position Effect: <1″ WC, any direction
Weight: 2 lbs
Wetted Materials: 316 Stainless steel
Housing: Powder coated cast alloy
Identification: Laser etched onto body
ELECTRICAL CONNECTION:
B ( ): Alternate electrical connector
ALTERNATE PRESSURE PORTS:
Y ( ): Alternate pressure ports
PERFORMANCE OPTIONS:
DG: Improved temperature compensation to ±1.0% FSO per 100°F
DH: Special ranging
DK: Special shunt calibration setting
DM: Modified full scale output
EA: Special calibration run
NH: Customer specified identification
PW: 1/8 DIN digital indicator
Note:
Application of some available options may affect standard performance.