Hastelloy, CIP, 3A, 0-33″ wc thru 750″ wc
359 is designed for 3A sanitary clean in place applications. 359 comes standard with Hastelloy wetted parts, providing excellent corrosion resistance to caustic materials. 359 has sealed external adjustments and capable of being ranged down if lower range measurements are required.
Features
Many Options available
ShuntCal
Pressure Applications
Full Scale Pressure Range (FSPR): 0-100″, 300″, 750″, 900″ WC
Combined Accuracy (Non-Linearity, Hysteresis, Repeatability): ≤±.2% FSO
Full Scale output (FSO): 16 mA
Resolution: Infinite
Long Term Stability: ≤±0.25% FSO per 6 months
Response Time (Mechanical and Electrical combined): ≤10 mSec to reach 90% FSO
Thermal recovery time: 50 Sec to reach 90% FSO
Temperature Effect on Zero: ≤±1.5% FSO per 100°F
Temperature Effect on Span: ≤±1.5% FSO per 100°F
Temperature Effect on Calibration Signal: ≤±2.0% FSO per 100°F
Compensated Temperature Range: 35°F to 170°F
Process Temperature Limits: -20°F to 220°F
High Temperature Option: -20°F to 300°F at 70° ambient temperature
Ambient Temperature Limits: -40°F to 250°F
Sensor Technology: Silicon Piezoerestictive
Supply Voltage: 9 to 30 VDC
Power Supply Regulation: ≤±0.01% FSO per volt
Output Signal: 4 to 20 mA
Load Impedance: 1500 Ohms max at 40 VDC
Zero Balance: 4 mA ±1% FSO
Zero Adjustment: -100% FSPR (Elevation) to 80% FSPR (Suppression). Coarse and fine adjustments standard
Span: 20 mA ±1% FSO
Span Adjustment: 3:1 Ranging
Range Calibration Signal: 30% of FSPR , externally switched
Calibration Signal Accuracy: <±0.2% FSO. The exact signal to pressure correlation is provided with each unit.
Circuit Protection: Varistor protected across the input leads for surges above 55V and currents to 250 Amps peak with a pulse width of 8 to 20 µsec. Reverse polarity protected.
Insulation Resistance: > 200 MegOhms to case ground
RFI/EMI Suppression: Negligible effect to 500 Mhz at 5 watts direct contact
Electrical Connection: 1/2″ NPT (M), 3 wires, 18 AWG, 36″ Length
Wiring Color:
Red +Signal
Black -Signal
Green Case Ground
Pressure Connection: Flush mount sensor mates with
Proof Pressure: 2x rated range
Burst Pressure: 3x rated range
Oil Fill: Less than 0.66 ml of DC 200 silicone oil
Measured Fluids: Any gas or liquid compatible with Hastelloy C-276 steel and silicone O-Ring
Weight: 4 lbs. nominal
Enclosure Materials: 316L stainless steel
Wetted Materials: Hastelloy C-276
Identification: Laser etched onto body
HD: Short length for single wall tanks
HE: Extra long length for King Receiver #1777-3
GA: Viton O-Ring
GB: Teflon O-Ring
GE: Buna-N O-Ring
NSR: Non Standard Ranging
- Mounting Bracket
- Conduit Connector
- Loop Powered Digital Indicator
- Protective Cover