3A approved, Flush Machined Diaphragm Sensor, Tri-Clamp Fitting
Viatran technology allows for accurate pressure measurement up to 1000 PSI. The transmitter also has no moving parts, isolation diaphragm, or oil fill to contaminate your process fluid.
Features
Many Options available
All Stainless Steel construction
A flush diaphragm inhibits bacterial growth and facilitates Clean in Place (CIP) systems.
The quick-disconnect Tri-clamp connections make these transmitters ideal for pharmaceutical, dairy and food processing applications where frequent cleaning is required.
Full Scale Pressure Range: 0 – 100, 400, 1000 PSIS, PSIA
Combined Accuracy (Non-Linearity, Hysteresis, Repeatability): ≤0.35% FSO
Full Scale Output (FSO): 16 mA at 70°F (21°C)
Resolution: Infinite
Long Term Stability: ≤±0.25% FSO per 6 months
Pressure Connection Effect Zero Balance: ≤±0.1%
Response Time (mechanical & electrical combined): ≤50 mSec
Temperature Effect on Zero: ≤±2% FSO per 100°F (37°C)
Temperature Effect on Span: ≤±1% FSO per 100°F (37°C)
Temperature Effect on Calibrated Signal: ≤±1& FSO per 100°F (37°C)
Operating Temperature Range: 0°F to 180°F (-17°C to 82°C)
Process Temperature Range: -65°F to 250°F (-53°C to 121°C)
Storage Temperature Limits: -65°F to 250°F (-53°C to 121°C)
Sensor Technology: Bonded foil strain gage
Supply Voltage: 12 to 30 Vdc
Power Supply Regulation: ≤±0.04% FSO per Volt
Output Signal: 4 – 20 mA at 70°F (21°C)
Load Impedance: 1925 Ohms max at 40 Vdc
Ripple: ≤±0.08% FSO
Zero Balance: 4 mA ±5% FSO at 70°F (21°C)
Zero adjustments: 5:1 turndown, externally 30 PSI min range
Range Calibration Signal: 20% of ±1.0% of FSPR, externally switched. Exact signal to pressure correlation is provided with each unit
Circuit Protection: Varistor protected across the input leads for surges above 38 V and currents to 250 Amps peak with a pulse width of 8-20 µSecs. Reverse polarity protected
Bridge Resistance: 5000 Ohms nominal
Insulation Resistance: ≤100 MegOhms at 50 Vdc
RFI/EMI Suppression: ≤1% FSO output change at 30 V meter, 10-1000 mhz
Electrical Connection: 1/2” NPT male conduit, 3 wires, 18 AWG, 36”
Color Wiring:
Red +Power/Signal
Black -Power/Signal
Green Case Ground
Pressure Connection: 1 1/2”, 2”, 2 1/2” Tri-clamp
Proof Pressure: 1.5 times rated range
Burst Pressure: ≤3 times rated range or max orange of clamp and tubing, whichever is less
Enclosure Materials: 15-5, 304, and 316 stainless steel
Wetted Materials: 316 stainless steel
Identification: Laser etched onto body
Measured Fluids: Any gas or liquid compatible with 316 stainless steel
BZ: Mini change connector
DG: Improved temperature compensation
DH: Special range (350 only)
EA: Special calibration
JJ: Direct mount indicator with Explosion Proof housing attached to transmitter
MD: FM Label
NH: Customer specified identification
PW: 1/8 DIN digital indicator
ZP: CIA-C814-10-6P-10-0A1
- Tri-Clamp Clamp
- Tri-Clamp Gasket
- Conduit Connector