0%

MODEL 374 DIFFERENTIAL PRESSURE TRANSMITTER

Low Range Differential Pressure, 1000 psi Line Pressure

Viatran’s Model 374 differential pressure transmitters are extremely accurate and durable units, designed specifically for test applications. The variable capacitance sensing technology provides extremely high overpressure protection, and long range stability, as well as high accuracy of 0.15% BFSL.

Features

High Accuracy

Many Options available

Low Pressure Applications

 

 

The Model 374 differential pressure transmitter measures pressure ranges from 5″ W.C. to 100 PSID and provides a 4-20 mA output signal.

All wetted surfaces, including flanges and diaphragms, are constructed of 316 stainless steel with a sealing Viton® O-Ring for excellent corrosion resistance.

A standard 1,000 PSI static line pressure and single side overpressure rating are featured with these transmitters.

For applications that require a higher static line pressure rating, 3,000 PSI is available with optional flanges.

Viatran Model 374 also features an internal calibration circuit for easy field set-up, a quick disconnect electrical connection and external zero and span controls.

A special option called fast response enables the unit to accurately respond to changes in pressure in approximately one tenth of the standard time.

These features make the Model 374 ideal for most industrial test and flow applications.

Full Scale Pressure Ranges:

  • 0-5, 10, 20, 50, 100, 300, 750″ W.C.D.
  • 0-15, 50, 100 PSID

Nonlinearity (Best Fit Straight Line):  ≤±0.15% FSO

Hysteresis:  ≤±0.08% FSO

Repeatability:  ≤ ±0.06% FSO

Full Scale Output (FSO):  16 mA

Resolution:  Infinite

Long Term Stability:   ≤±0.1% FSO per 6 months

Zero Shift w/Line Pressure (%FSO/1000 PSI):

  • 5” WC to 100” WC : ≤ 4%
  • 300” WC to 100 PSI: ≤ 6%

Span Shift w/Line Pressure (%FSO/1000 PSI):

  • 5” WC to 100” WC : 0 to -6%
  • 300” WC to 100 PSI : 0 to -4%

Zero Shift After 1000 PSI Overload:

  • Single Side: ≤± 0.1% FSO
  • Alternate Sides: ≤±0.5% FSO

Compensated Temperature Range:  70°F to 170°F (21°C to 76°C)

Operating Temperature Range:

  • 5″WC to 50″WC (0° F to +170° F)
  • 100″WC to 100 PSI (-40° F to +170° F)

Storage Temperature Limits:

  • 5″WC to 50″WC (0° F to +170° F)
  • 100″WC to 100 PSI (-40° F to +170° F)

Temperature Effect on Zero:  ≤± 2.0% FSO per 100° F

Temperature Effect on Span:  ≤± 2.0% FSO per 100° F

Supply Voltage:  9 to 30 Vdc

Power Supply Regulation:  ≤±0.0001% FSO per Volt change over the supply voltage range

Output Signal:  4 to 20 mA

Load Impedance:

  • 0 Ohms at 10 VDC
  • 1600 Ohms maximum at 42 VDC

Zero Adjustment:  ±5% FSO min./ ±50% FSO max.

Span Adjustment:  ± 10% FSO min. / ±50% FSO max.

Calibration Signal:  80% of the FSPR, by shorting pins E & F

Calibration Signal Accuracy:  ≤±0.1% of the stated value

Circuit Protection:  Reverse polarity protected

Insulation Resistance:  >1000 MegOhms to case ground at 50 Vdc and 70° F

Response Time:  10% to 90% FS (Faster response available with NF option.)

Electrical Connection:  Bendix PT02E-10-6P, mates PT06E-10-6S (SR)

Pin Outs:

Pin A              + Signal

Pin B               – Signal

Pin C                 Calibrate

Pin D                 Calibrate

Pin E                  No connection

Pin F                  No connection

Wetted Parts:  316 Stainless steel and Viton O-Ring

Housing:  304 and 316 Stainless Steel with an Aluminum alloy, black zinc-cobalt plated electrical connector

Weight:  3.5 lbs. (6.5 lbs. with optional flanges)

Identification:  Laser etched onto body

Pressure Connection:  1/4″ – 18 NPT female

Static Pressure:  1000 PSI maximum (3000 PSI – optional)

Proof Pressure:  1000 PSI single sided (3000 PSI – optional)

Burst Pressure:  1500 PSI (4500 PSI – Optional)

Diaphragm Displacement:  0.002 cubic inches at FSPR

Pressure Cavity Volume:

  • Standard Flanges: 0.4 cubic inches
  • Optional Process Flanges : 1.5 cubic inches

Fill Fluid:  Dow DC200 Silicone oil

Mounting:  May be supported by process piping or by optional mounting bracket

ELECTRICAL CONNECTION:

B ( ):  Alternate electrical connector

PERFORMANCE OPTIONS:

DG:  Improved temperature compensation to ±1.0% FSO per 100°F

DH:  Special ranging

DK:  Special shunt calibration setting

DM:  Modified full scale output

DQ:  Cleaning for oxygen service

EA:  Special calibration run

GE:  Buna ‘N’ O-Rings

NB:  Alternate process flanges for increased pressure rating

NF:  Fast response time

NH:  Customer specified identification

NM:  Alternate output signal (3mV/V)

ALTERNATE PRESSURE PORTS:

Y ( ):  Alternate pressure ports

APPROVAL & CERTIFICATE OPTIONS:

FA:  Russian Metrology Certificate (Model 374 only)

Note:

Application of some available options may affect standard performance.