MODEL 520 HAMMER UNION PRESSURE TRANSMITTER

4-20 mA output, 2″ 2002 fitting, Hazardous Location Approval Options

Viatran’s Model 520 Hammer Union Pressure Transmitter offers superior construction and the rugged performance that we have built our reputation on.

Features

2002 Hammer Union Pressure Fitting

 Many Options available

 ShuntCal

High-Pressure Applications

Full Scale Pressure Ranges:  0-5K, 0-6K, 0-10K, 0-15K, 0-20K, 0-25K PSIS

Combined Accuracy (BFSL):  (Non-Linearity, Hysteresis & Repeatability)     ≤ ± 0.25% FSO

Full Scale Output (FSO):  16.00 mA ±1% FSO @70°F

Zero Balance.:  4 mA ±1% FSO @70°F

Compensated Temperature Range:  -40°F to 140°F (4°C to 60°C)

Operating Temperature Range:  -40°F to 185°F (-40°C to 85°C)

Storage Temperature Range:  -67°F to 302°F (-55°C to 150°C)

Long Term Stability (%FSO):  ≤ ± .25% FSO per 6 months

Thermal Effect on Zero:  ≤± 1% FSO per 100°F Typical

Thermal Effect on Span:  ≤± 1% FSO per 100°F Typical

Output Signal:  4-20 mA @70°F

Supply Voltage:  10.5 to 28 Vdc

Power Supply Regulation:  <± .01% FSO per volt

Load Impedance:  900 ohms @ 28 VDC decreasing linearity to 0 ohms @ 9 VDC

Circuit Protection:  Reverse polarity protected

RFI / EMI:

  • <1% FSO output change with 3V Rms from 150 kHz to 80 MGz
  • (80% AM modulated at 1 kHz) applied to power supply and signal lines
  • [IEC 61000-4-6 radio frequency common mode immunity],
  • 1% output change when exposed to a radiated electromagnetic
  • field of 10 V/m from 80 MHz to 1 GHz AM modulated at 1 kHz and 3 V/m
  • 1.4 GHz to 2.7 GHz. [IEC 61000-4-3 Radiated electromagnetic field immunity]

Voltage Spike Protection:  Withstand 1000 volt spike per EN 61000-4-5

Insulation Resistance:  < 5 nS

Response Time:  < 1 millisecond to reach 90% of FSO

Range Calibration Signal:  100% FSO ±10% by exciting pins E&F

Calibration Power Supply Voltage:  8.5 -28 VDC

Calibration Signal Accuracy:  Readings on calibration certificate are within ±0.2% FSO of actual Cal signal output

Bridge Resistance:  10K ohms, nominal

Standard Electrical Connection:  Mates with 6 pin, Hermetic, Box Mount, Shell Size 10, MIL-C-26482 bendix type connector

PIN OUTS:

PIN A    + Power / Signal

PIN B     – Power / Signal

PIN C       No Connection

PIN D       No Connection

PIN E    + Calibration

PIN F    –  Calibration

Standard Pressure Port:  Male hammer union 2 inch #2002

Pressure Cavity Volume:  Standard: 0.45 cubic inches

Zero Effect from Installation:  0.3% FSO w/200 ft-lbs torque on union #2002

Shock Sensitivity:  1000 g, 0.5 ms half sine wave pulse shall not cause change in calibration

Proof Pressure:  1.67X range or 30,000 PSI max

Burst Pressure:  3 Times full scale pressure range, limited by union #2002: 30K PSI

Wetted Materials:  NACE compliant Inconel 718 (MR0175/ISO 15156-3:2009(E))

Enclosure Material:  304 Stainless Steel

Identification:  Laser marked on body of unit

Enclosure Rating:  IP68*, NEMA 6P*

Weight:  4.0 lbs. nominal

* Pending approvals

DC:  Compensated temperature -40°F to 140°F

DG:  Improved temperature compensation

DH:  Special Range

DN:  Improved accuracy

EA:  Special Calibration Run

EH:  Compensated temperature range 40°F to 180°F

LW:  Narrow adapter for banding

NA:  Carrying handle attached

NH:  Customer specific identification

NP:  Protective ring cage

NQ:  Protective criss-cross cage

TW:  Russia Intrinsic Safety

Z():  Special connectors