0%

MODEL 385 PRESSURE TRANSMITTER

5x proof, 4-20 mA output, Blender Pressure Measurement

The Model 385 Flush Tip – Zero Cavity design offers an Isolated sensor assembly that virtually eliminates installation torque effect and is able to withstand pressure spikes up to 5x proof pressure and 20x burst pressure.

Features

 RoHS Compliant

All Stainless Steel construction

 Shunt Calibration circuit option

 

Full Scale Pressure Ranges:  0-50,100, 150, 160, 200, 250, 300, 400, 500, 1,000 PSIG / PSIS

Static Error Band:  ≤±0.5% FSO (Includes BFSL, Hysteresis and Repeatability by RSS)

Compensated Temperature Range:  70°F to 170°F (21°C to 77°C)

Operating Temperature Range:  -40°F to 185°F (-40°C to 85°C)

Storage Temperature Range:  -40°F to 250°F (-40°C to 120°C)

Long Term Stability (%FSO):  ≤±0.5% FSO per 6 months

Thermal Effect on Zero:  ≤±2% FSO per 100°F Typical

Thermal Effect on Span:  ≤±2% FSO per 100°F Typical

Output Signal:  4-20 mA

Supply Voltage:  8-28 Vdc

Power Supply Regulation:  <±.05% FSO per volt

Load Impedance:  926 Ohms maximum at 28 volts DC

Circuit Protection:  Reverse polarity protected, CE marked

RFI / EMI:  CE EMC compliant as per IEC EN 61326-1 and EN 61326-2-3 Annex BB

Voltage Spike Protection:  Withstand 1000 volt spike per EN 61000-4-5

Insulation Resistance:  <5 nS

Response Time:  <2 mSec for 10-90% of final value

Electrical Connection:  Bendix PT02E-10-6P, mates PT06E-10-6S (SR) (BH option)

Pin Outs:

Pin A                + Power / Signal

Pin B                 – Power / Signal

Pin C                   No connection

Pin D                   No connection

Pin E                   AC Ground

Pin F                   No connection

Shell                   Case Ground

Standard Pressure Port:  1/2″ NPT (M)

Zero Effect from Installation:  <±0.10% at 25 to 50 ft lbs

Proof Pressure:  5x

Burst Pressure:  20x

Wetted Materials:  15-5 PH and 304L Stainless Steel (Inconel 718 optional)

Weight:  8 oz. nominal

PRESSURE RANGES:

AH:  0-50 PSI

AM:  0-100 PSI

AN:  0-150 PSI

CA:  0-160 PSI

AP:  0-200 PSI

AQ:  0-250 PSI

AR:  0-300 PSI

AT:  0-400 PSI

AU:  0-500 PSI

AY:  0-1,000 PSI

ALTERNATE ELECTRICAL CONNECTIONS:

BH:  Welded – 6 Pin bayonet shell size 10

ZE:  Welded – 4 Pin Hermetic,shell size 14S, (MIL-DTL-5015H)

ZU:  Welded- Direct Coupled Cable

PRESSURE CONNECTION:

VQ:  3/4″-16 UNF (M) (Includes Std Nitrile / NBR “O” ring)

VR:  G 1/2″ (M) (Includes Std Nitrile / NBR ED Seal according to DIN 3869)

PERFORMANCE OPTIONS:

DA:  Isolated Internal Shunt Cal at 80% Full Scale

DC:  Extended Compensated Temperature Range (Cold) -40°F to 170°F (-40°C to 77°C)

EA:  Special Calibration Run

EH:  Extended Compensated Temperature Range (Hot) +70°F to 185°F (21°C to 85°C)

GA:  “O” Ring or ED Seal- VITON® / FKM material

GD:  “O” Ring – EPDM material (not available with “VR” option)

NH:  Customer Specified Identification

PW:  1/8 DIN Digital Indicator

QK:  Inconel 718 – for all wetted parts (minimum range is 0-150 PSI)