4-20mA output, 150 – 10K PSI
The Model 386 Flush Tip – Zero Cavity design offers an Isolated sensor assembly that virtually eliminates installation torque effect and is able to withstand pressure spikes up to 1.5x proof pressure and 5x burst pressure (or 30,000 PSI, whichever is less).
Features
Shunt Calibration circuit option
All Stainless Steel constructions
RoHS Compliant
Full Scale Pressure Ranges: 0-100, 150, 160, 200, 300, 500, 750, 1000, 1500, 2000, 3000, 5000, 7500, 10,000 PSIG / PSIS
Static Error Band: ≤±0.5% FSO (Includes BFSL, Hysteresis and Repeatability by RSS)
Compensated Temperature Range: 70°F to 170°F (21°C to 77°C)
Operating Temperature Range: -40°F to 185°F (-40°C to 85°C)
Storage Temperature Range: -40°F to 250°F (-40°C to 120°C)
Long Term Stability (%FSO): ≤±0.25% FSO per 6 months
Thermal Effect on Zero: ≤±2% FSO per 100°F Typical
Thermal Effect on Span: ≤±2% FSO per 100°F Typical
Output Signal: 4-20 mA
Supply Voltage: 8-28 Vdc
Power Supply Regulation: <±.05% FSO per volt
Load Impedance: 926 Ohms maximum at 28 volts DC
Circuit Protection: Reverse polarity protected, CE marked
RFI / EMI: CE EMC compliant as per IEC EN 61326-1 and EN 61326-2-3 Annex BB
Voltage Spike Protection: Withstand 1000 volt spike per EN 61000-4-5
Insulation Resistance: <5 nS
Response Time: <2 mSec for 10-90% of final value
Electrical Connection: Bendix PT02E-10-6P, mates PT06E-10-6S (SR) (BH option)
Pin Outs:
Pin A + Power / Signal
Pin B – Power / Signal
Pin C No connection
Pin D No connection
Pin E AC Ground
Pin F No connection
Shell Case Ground
Standard Pressure Port: 1/2″ NPT (M)
Zero Effect from Installation: <±0.10% at 25 to 50 ft lbs
Proof Pressure: 1.5x
Burst Pressure: 5X (or 30,000 PSI, whichever is less)
Wetted Materials: 15-5 PH and 304L Stainless Steel (Inconel 718 optional)
Weight: 8 oz. nominal
PRESSURE RANGES:
AM: 0-100 PSI
AN: 0-150 PSI
CA: 0-160 PSI
AP: 0-200 PSI
AR: 0-300 PSI
AU: 0-500 PSI
AW: 0-750 PSI
AY: 0-1,000 PSI
AZ: 0-1,500 PSI
BA: 0-2,000 PSI
BC: 0-3,000 PSI
BF: 0-5,000 PSI
BH: 0-7,500 PSI
BM: 0-10,000 PSI
ALTERNATE ELECTRICAL CONNECTIONS:
BH: Welded – 6 Pin bayonet shell size 10
ZE: Welded – 4 Pin Hermetic,shell size 14S, (MIL-DTL-5015H)
ZU: Welded- Direct Coupled Cable
PRESSURE CONNECTION:
VQ: 3/4″-16 UNF (M) (Includes Std Nitrile / NBR “O” ring)
VR: G 1/2″ (M) (Includes Std Nitrile / NBR ED Seal according to DIN 3869)
PERFORMANCE OPTIONS:
DA: Isolated Internal Shunt Cal at 80% Full Scale
DC: Extended Temperature Range (Cold) -40°F to 170°F (-40°C to 77°C)
DG: Improved Temperature Compensation to ± 1° FSO shift per 100°F
DH: Special Range
DN: Improved Non-linearity
EA: Special Calibration Run
EH:
Extended Temperature Range (Hot) +70°F to 185°F (21°C to 85°C): Extended Temperature Range (Hot) +70°F to 185°F (21°C to 85°C)
GA: “O” Ring or ED Seal- VITON® / FKM material
GD: “O” Ring – EPDM material (not available with “VR” option)
NH: Customer Specified Identification
PW: 1/8 DIN Digital Indicator
QK: Inconel 718 – for all wetted parts (minimum range is 0-150 PSI)