0-40″wc thru 835’wc, 0.75″ diameter, PUR Cable Standard, Stainless Steel Sensor and Housing
The Model 59S “Slimline” Level Transmitter is designed for level measurement where space is limited. 0.75″ diameter and 4.4″ length makes this product ideal for tight spaces. Higher accuracy option is available to .10%. PVC and FEP cables are also available. A complete range of accessories for use in level applications are available, many from stock.
Features
IP-68 Rated
All Stainless Steel construction
High Accuracy
RoHS Compliant
Designed with a slim 0.75 inch diameter body to enable it to fit small access ports, you can use it to measure Liquid Level and Depth for Water and Waste Water applications, at Lift Stations, Shipboard, In-ground / Above Ground Tanks and with Inventory Tank Gauging.
Pressure Ranges: 0-50, 100 Inches Water Column, 0-2, 3, 5 PSI
Combined Accuracy (Non-Linearity, Hysteresis, Repeatability): ≤±0.50% FSO for ranges < 15 Ft. W.C.
Compensated Temperature Range: 2° to 122° F (0 to 50° C) ≥ 13.4 Ft. W.C., otherwise 32° to 158° F (0 to 70° C)
Operating Temperature Range: 14° to 158° F (-10 to 70° C) **Note: Medium must not freeze near sensor
Storage Temperature Range: -13° to 158° F (-25 to 70° C)
Long Term Stability (%FSO): ≤±0.1% FSO / year at reference conditions
Thermal Effect on Zero: ≤ +/- 2% FSO per 100° F for ≥ 13.4 Ft. W.C., otherwise ≤ +/- 0.8% FSO per 100° F
Thermal Effect on Span: ≤ +/- 2% FSO per 100° F for ≥ 13.4 Ft. W.C., otherwise ≤ +/- 0.8% FSO per 100° F
Pressure Connection: Protective POM cap
Ingress Protection: IP 68
Overpressure Limit: 2.4x Minimum
Burst Pressure: 5x Minimum
Weight: 0.22 lbs. (without cable)
Housing: 316L stainless steel
Sensor Diaphragm: 316L stainless steel
O-ring Seals: FKM or EPDM (customer specified)
Protective Cap: POM (Polyoxymethylene)
EA: Special Calibration Run
PW: Calibrate item with meter/display